%0 Dataset %T Heihe River eco hydrological remote sensing experiment: multi-scale observation experiment of surface evapotranspiration on non-uniform underlying surface - flux observation matrix data set (shenshawo desert station vortex correlator-2012) %J National Cryosphere Desert Data Center %I National Cryosphere Desert Data Center(www.ncdc.ac.cn) %U http://www.ncdc.ac.cn/portal/metadata/30b5720f-bffd-451e-b691-9a567f124157 %W NCDC %R 10.12072/ncdc.NIEER.db0034.2020 %A Liu shaomin %K hydrometeor;Latent heat flux;CO2 flux;Sensible heat flux;Eddy correlator %X The data set contains the eddy related flux observation data of shenshawo station in the flux observation matrix from June 1 to September 15, 2012. The station is located in Zhangye City, Gansu Province, with the underlying surface of desert. The longitude and latitude of the observation point are 100.49330e, 38.78917n and 1594.00m above sea level. The eddy correlator frame is 4.6m high, the sampling frequency is 10Hz, the ultrasonic direction is due north, and the distance between the ultrasonic anemometer and CO2 / H2O analyzer is 15cm.The original observation data of eddy correlator is 10Hz. The released data is the 30 minute data post processed by edire software. The main processing steps include: field value elimination, delay time correction, coordinate rotation (quadratic coordinate rotation), frequency response correction, ultrasonic virtual temperature correction and density (WPL) correction. At the same time, the quality of each flux value is evaluated, mainly the atmospheric stability( Δ St) and turbulence similarity characteristics (ITC). The 30 min flux value output by edire software is also screened: (1) eliminate the data when the instrument is wrong( 2) Eliminate the data 1H before and after precipitation( 3) Eliminate the data with a loss rate of more than 3% every 30min of 10Hz original data( 4) Eliminate the observation data of weak turbulence at night (U less than 0.1M / s). The average period of observation data is 30 minutes, 48 data a day, and the missing data is marked as - 6999. Suspicious data caused by instrument drift and other reasons shall be identified in red font.The published observation data include: date / time, wind direction WDIR (°), horizontal wind speed wnd (M / s), standard deviation of lateral wind speed STD_ Uy (M / s), ultrasonic virtual temperature TV (℃), water vapor density H2O (g / m3), carbon dioxide concentration CO2 (mg / m3), friction velocity ustar (M / s), stability Z / L (dimensionless), sensible heat flux HS (