    "title_cn": "黑河生态水文遥感试验：黑河流域中游二坝水库水体表面温度观测数据集（2012年）",
    "title_en": "Heihe River eco hydrological remote sensing test: observation data set of water surface temperature of Erba reservoir in the middle reaches of Heihe River Basin (2012)",
    "ds_abstract": "<p>&emsp;&emsp;二坝水库红外温度和水面温度观测系统架设目的在于为航空TASI、WiDAS和L波段飞行提供水体表面温度的数据。\n</p>\n<p>&emsp;&emsp;观测地点：选择张掖城东14km,甘州区碱滩镇二坝村旁的二坝水库作为观测点。该观测点坐标：38°54'57.14\"N，100°36'57.39\"。\n</p>\n<p>&emsp;&emsp;测量仪器：观测内容包括一个垂直对水面的SI-111红外温度探头，一个正南天顶角35度对天观测的SI-111红外温度探头（2012年新购置仪器，其出厂时默认设置的地表发射率为1，试验期间未进行黑体定标）。2个漂浮在水面以下0cm109SS-L温度传感器，数采为Campell CR-1000，自动采集，GPRS无线传输至综汇系统。探头架高3米，离岸距离3.4m。\n</p>\n<p>&emsp;&emsp;测量时间：仪器从2012年5月27日起开始正常观测，至9月27日进行不间断地24小时观测，5秒钟记录一次数据，输出5秒钟和1分钟2组值。\n</p>\n<p>&emsp;&emsp;数据内容：垂直水体表面温度（TarT_Sur，未进行地表比辐射率、背景温度的校正）、对天空温度（TarT_Atm，未进行天空背景比辐射率的校正），水面0cm直接测量温度（WaterT_1，WaterT_2）。数据最终被存储为1天1个独立文本文件，数据命名方式：数据格式+观测点名称+数据采样时间+日期+时间.dat。详细的数据表头信息见数据内的数据表头说明。</p>",
    "ds_source": "<p>&emsp;&emsp;张掖城东14km,甘州区碱滩镇二坝村旁的二坝水库作为观测点。",
    "ds_process_way": "<p>&emsp;&emsp;包括一个垂直对水面的SI-111红外温度探头，一个正南天顶角35度对天观测的SI-111红外温度探头（2012年新购置仪器，其出厂时默认设置的地表发射率为1，试验期间未进行黑体定标）。2个漂浮在水面以下0cm109SS-L温度传感器，数采为Campell CR-1000，自动采集，GPRS无线传输至综汇系统。探头架高3米，离岸距离3.4m。</p>",
    "ds_quality": "<p>&emsp;&emsp;垂直水体表面温度（TarT_Sur，未进行地表比辐射率、背景温度的校正）、对天空温度（TarT_Atm，未进行天空背景比辐射率的校正），水面0cm直接测量温度（WaterT_1，WaterT_2）。</p>",
    "ds_acq_start_time": "2012-06-04 00:00:00",
    "ds_acq_end_time": "2012-10-05 00:00:00",
    "ds_acq_place": "黑河流域, 中游人工绿洲试验区, 二坝水库",
    "ds_acq_lon_east": 100.61583333333333,
    "ds_acq_lat_south": 38.91583333333333,
    "ds_acq_lon_west": 100.61583333333333,
    "ds_acq_lat_north": 38.91583333333333,
    "ds_acq_alt_low": null,
    "ds_acq_alt_high": null,
    "ds_share_type": "apply-access",
    "ds_total_size": 71065028,
    "ds_files_count": 2,
    "ds_format": "dat",
    "ds_space_res": null,
    "ds_time_res": "日",
    "ds_coordinate": "WGS84",
    "ds_projection": "",
    "ds_thumbnail": "92208d2e-8f25-484e-9858-de3ac24c6f3a.png",
    "ds_thumb_from": 0,
    "ds_ref_way": "",
    "paper_ref_way": "",
    "ds_ref_instruction": "本数据由“黑河生态水文遥感试验（HiWATER）”产生，用户在使用数据时请在正文中明确声明数据的来源，并在参考文献部分引用本元数据提供的引用方式。",
    "ds_from_station": null,
    "organization_id": "c94b3578-20da-4346-9de9-c702b6ca8983",
    "ds_serv_man": "敏玉芳",
    "ds_serv_phone": "0931-4967596",
    "ds_serv_mail": "ncdc@lzb.ac.cn",
    "doi_value": "",
    "subject_codes": null,
    "quality_level": 3,
    "publish_time": "2021-08-31 09:13:13",
    "last_updated": "2023-08-23 16:47:40",
    "protected": false,
    "protected_to": null,
    "lang": "zh",
    "cstr": "11738.11.ncdc.NIEER.2021.1879",
    "i18n": {
        "en": {
            "title": "Heihe River eco hydrological remote sensing test: observation data set of water surface temperature of Erba reservoir in the middle reaches of Heihe River Basin (2012)",
            "ds_format": "",
            "ds_source": "<p>&emsp; 14km east of Zhangye City, the Erba reservoir next to Erba village, Jiantan Town, Ganzhou district is used as the observation point.",
            "ds_quality": "<p>&emsp; Vertical water surface temperature (tart)_ Sur, without correction of surface specific emissivity and background temperature), sky temperature (tart)_ ATM, without sky background specific emissivity correction), water surface 0cm directly measured temperature (water t)_ 1，WaterT_ 2）。</ p>",
            "ds_ref_way": "",
            "ds_abstract": "<p>  The infrared temperature and water surface temperature observation system of Erba reservoir is set up to provide water surface temperature data for aviation TASI, widas and L-band flights.\n</p>\n<p>  Observation site: the Erba reservoir, 14km east of Zhangye City and next to Erba village, Jiantan Town, Ganzhou District, is selected as the observation point. Coordinates of the observation point: 38 ° 54'57.14 \"n, 100 ° 36'57.39\".\n</p>\n<p>  Measuring instrument: the observation contents include a si-111 infrared temperature probe perpendicular to the water surface and a si-111 infrared temperature probe observing the sky at a zenith angle of 35 degrees due south (the instrument was newly purchased in 2012, the default surface emissivity was 1 when it was delivered from the factory, and blackbody calibration was not carried out during the test). Two 0cm109ss-l temperature sensors floating below the water surface, data acquisition is Campell cr-1000, automatic acquisition, GPRS wireless transmission to the comprehensive collection system. The probe frame is 3M high and the offshore distance is 3.4m.\n</p>\n<p>  Measurement time: the instrument starts normal observation from May 27, 2012 to September 27, 2012, continuously observes for 24 hours, records data once in 5 seconds, and outputs two groups of values in 5 seconds and 1 minute.\n</p>\n<p>  Data content: vertical water surface temperature (tart)_ Sur, without correction of surface specific emissivity and background temperature), sky temperature (tart)_ ATM, without sky background specific emissivity correction), water surface 0cm directly measured temperature (water t)_ 1，WaterT_ 2）。 The data is finally stored as an independent text file for one day. The data naming method is: data format + observation point name + data sampling time + date + time. Dat. For detailed data header information, see the data header description in the data</p>",
            "ds_time_res": "日",
            "ds_acq_place": "Heihe River Basin, artificial oasis experimental area in the middle reaches, Erba reservoir",
            "ds_space_res": "",
            "ds_projection": "",
            "ds_process_way": "<p>&emsp; It includes a si-111 infrared temperature probe perpendicular to the water surface and a si-111 infrared temperature probe for sky observation with a zenith angle of 35 degrees due to the South (the instrument was newly purchased in 2012, the default surface emissivity was 1 when it was delivered from the factory, and blackbody calibration was not carried out during the test). Two 0cm109ss-l temperature sensors floating below the water surface, data acquisition is Campell cr-1000, automatic acquisition, GPRS wireless transmission to the comprehensive collection system. The probe frame is 3M high and the offshore distance is 3.4m</ p>",
            "ds_ref_instruction": "                                                            \nThis data is generated by \"Heihe eco hydrological remote sensing experiment (hiwater)\". When using the data, users should clearly state the source of the data in the text and quote the reference method provided by this metadata in the reference part."
        }
    },
    "submit_center_id": "ncdc",
    "data_level": 0,
    "license_type": "https://creativecommons.org/licenses/by/4.0/",
    "doi_reg_from": "reg_local",
    "cstr_reg_from": "reg_local",
    "doi_not_reg_reason": null,
    "cstr_not_reg_reason": null,
    "is_paper_in_submitting": false,
    "ds_topic_tags": [
        "水面温度",
        "水体",
        "辐射定标",
        "定标观测",
        "地表辐射温度",
        "水域",
        "土地利用",
        "地表辐射特性"
    ],
    "ds_subject_tags": [
        "自然地理学"
    ],
    "ds_class_tags": [],
    "ds_locus_tags": [
        "中游人工绿洲试验区",
        "二坝水库",
        "黑河流域"
    ],
    "ds_time_tags": [
        2012
    ],
    "ds_contributors": [
        {
            "true_name": "马明国",
            "email": "mmg@lzb.ac.cn",
            "work_for": "中国科学院西北生态环境资源研究院",
            "country": "中国"
        }
    ],
    "ds_meta_authors": [
        {
            "true_name": "马明国",
            "email": "mmg@lzb.ac.cn",
            "work_for": "中国科学院西北生态环境资源研究院",
            "country": "中国"
        }
    ],
    "ds_managers": [
        {
            "true_name": "马明国",
            "email": "mmg@lzb.ac.cn",
            "work_for": "中国科学院西北生态环境资源研究院",
            "country": "中国"
        }
    ],
    "category": "遥感及产品"
}