    "created": "2021-07-01 01:58:39",
    "updated": "2026-04-19 14:48:45",
    "id": "f0edaf1f-9365-489a-8ff3-507bfa7bce96",
    "version": 5,
    "ds_topic": null,
    "title_cn": "低温水泥浆水化热性能测试数据集（2017-2020年）",
    "title_en": "Test data set of hydration heat performance of low temperature cement slurry (2017-2020)",
    "ds_abstract": "<p>&emsp;&emsp;2019年采用室内实验方法完成了低温水泥浆水化热性能测试，形成了数据集，达到考核指标，0℃条件下8h抗压强度≥3.5MPa，稠化时间可调，泵入时间可控，低温强度发展快。观测要素包括水化热等。共计开展室内实验30次，实验数据集完全开放共享。该项目室内实验时间范围始于2019年1月1日，止于2019年12月31日，资源时间覆盖范围是2017年9月20日至2020年3月20日，实验地北京。</p>",
    "ds_source": "<p>&emsp;&emsp;实验试验，自主产生。</p>",
    "ds_process_way": "<p>&emsp;&emsp;数据采集使用中国石化石油工程技术研究院固井实验室实验设备，水泥水化热分析仪技术参数：对水泥水化热过程进行测试，温度范围：+3℃~+50℃，环境温度：根据测试温度恒温到相应温度，操作温度：环境温度+5℃，固体重量：≤10g，液体重量：≤5g。</p>",
    "ds_quality": "<p>&emsp;&emsp;数据质量良好。</p>",
    "ds_acq_start_time": "2017-09-20 00:00:00",
    "ds_acq_end_time": "2020-03-20 00:00:00",
    "ds_acq_place": "北京市",
    "ds_acq_lon_east": null,
    "ds_acq_lat_south": null,
    "ds_acq_lon_west": null,
    "ds_acq_lat_north": null,
    "ds_acq_alt_low": null,
    "ds_acq_alt_high": null,
    "ds_share_type": "login-access",
    "ds_total_size": 32757,
    "ds_files_count": 3,
    "ds_format": "excel",
    "ds_space_res": null,
    "ds_time_res": "日",
    "ds_coordinate": "无",
    "ds_projection": "",
    "ds_thumbnail": "f0edaf1f-9365-489a-8ff3-507bfa7bce96.png",
    "ds_thumb_from": 0,
    "ds_ref_way": "",
    "paper_ref_way": "",
    "ds_ref_instruction": "",
    "ds_from_station": null,
    "organization_id": "aaf309a1-cdf4-4049-be08-c06f80c4061f",
    "ds_serv_man": "敏玉芳",
    "ds_serv_phone": "0931-4967596",
    "ds_serv_mail": "ncdc@lzb.ac.cn",
    "doi_value": "10.12072/ncdc.SRIPE.db1690.2022",
    "subject_codes": [
        "170.50"
    ],
    "quality_level": 3,
    "publish_time": "2022-02-25 11:49:31",
    "last_updated": "2025-05-29 11:37:06",
    "protected": false,
    "protected_to": null,
    "lang": "zh",
    "cstr": "11738.11.ncdc.SRIPE.db1690.2022",
    "i18n": {
        "en": {
            "title": "Test data set of hydration heat performance of low temperature cement slurry (2017-2020)",
            "ds_format": "Excel",
            "ds_source": "<p>&emsp; &emsp; Experimental experiments, independently generated. </p>",
            "ds_quality": "<p>&emsp; &emsp; The data quality is good. </p>",
            "ds_ref_way": "",
            "ds_abstract": "<p>    In 2019, indoor experimental methods were used to complete the hydration heat performance test of low-temperature cement slurry, forming a dataset that met the assessment indicators. The compressive strength at 0 ℃ for 8 hours was ≥ 3.5MPa, the thickening time was adjustable, the pumping time was controllable, and the low-temperature strength developed rapidly. Observation elements include hydration heat, etc. A total of 30 indoor experiments were conducted, and the experimental dataset was fully open and shared. The indoor experiment of this project started on January 1, 2019 and ended on December 31, 2019. The resource coverage period is from September 20, 2017 to March 20, 2020, and the experimental site is in Beijing. </p>",
            "ds_time_res": "日",
            "ds_acq_place": "Beijing",
            "ds_space_res": "",
            "ds_projection": "",
            "ds_process_way": "<p>&emsp; &emsp; The data was collected using experimental equipment from the cementing laboratory of Sinopec Petroleum Engineering Technology Research Institute. The technical parameters of the cement hydration heat analyzer are: to test the cement hydration heat process, temperature range:+3 ℃~+50 ℃, ambient temperature: constant temperature to the corresponding temperature according to the test temperature, operating temperature: ambient temperature+5 ℃, solid weight: ≤ 10g, liquid weight: ≤ 5g</p>",
            "ds_ref_instruction": ""
        }
    },
    "submit_center_id": "ncdc",
    "data_level": 0,
    "license_type": "CC BY 4.0",
    "ds_topic_tags": [
        "低温水泥浆，水化热性能",
        "抗压强度"
    ],
    "ds_subject_tags": [
        "地质学"
    ],
    "ds_class_tags": [],
    "ds_locus_tags": [
        "北京"
    ],
    "ds_time_tags": [
        2017,
        2018,
        2019,
        2020
    ],
    "ds_contributors": [
        {
            "true_name": "高德利",
            "email": "gaodeli@cup.edu.cn",
            "work_for": "中国石油大学（北京）",
            "country": "中国"
        }
    ],
    "ds_meta_authors": [
        {
            "true_name": "牛成成",
            "email": "niucc.sripe@sinopec.com",
            "work_for": "中国石油化工股份有限公司石油工程技术研究院",
            "country": "中国"
        }
    ],
    "ds_managers": [
        {
            "true_name": "高德利",
            "email": "gaodeli@cup.edu.cn",
            "work_for": "中国石油大学（北京）",
            "country": "中国"
        }
    ],
    "category": "其他"
}