Through the experimental study on the start-up speed of various filters, the fastest start-up filter column is determined; The best new manganese sand composite filter material (MTZ) is used for filtration test under different operating parameters, and the filtration cycle and backwash test are carried out to study and determine the best operating conditions for iron and manganese removal and the best backwash time, intensity and times of MTZ; The aging and oxidation problems of the new manganese sand composite filter media (MTZ) are also explored, and the mechanism of removing iron and manganese by MTZ is preliminarily explored, so as to provide reasonable parameters for practical application. The data set contains 229 data in total.
| collect time | 2021/01/01 - 2021/01/31 |
|---|---|
| collect place | Beijing |
| data size | 14.3 MiB |
| Data time resolution | day |
Indoor experiment, self generated.
Filtration test and flushing test were carried out to explore the aging and oxidation of the new manganese sand composite filter material (MTZ).
Good data quality.
| # | number | name | type |
| 1 | 2018YFC0406400 | National key R & D plan |
This work is licensed under
CC BY 4.0 (Creative Commons Attribution 4.0 International License).
| # | title | file size |
|---|---|---|
| 1 | 实体数据36 MTZ处理高铁锰矿井水动态试验数据集(2021年).rar | 14.3 MiB |
High iron manganese washing test oxidation new manganese sand composite filter material (MTZ)
-
-
©Copyright 2005-. Northwest Institute of Eco-Environment and Resources, CAS.
Donggang West Road 320, Lanzhou, Gansu, China (730000)